Topic: Frequency and duration of maintenance treatments | |
dell Replies: 1 Views: 3234 |
Forum: Iontophoresis Posted: Sun Aug 15, 2010 2:55 pm Subject: Frequency and duration of maintenance treatments |
Hi Markus, I have been treating my hands and feet with success using the Hidrex at 38V in Direct current (it has taken me a quite a few months of treatment to be able to tolerate 38V in direct curr ... |
|
Topic: new to Hidrex PS500 | |
dell Replies: 13 Views: 13645 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Sat May 22, 2010 7:50 am Subject: new to Hidrex PS500 |
Hi Markus, I have tried using the tips provided however I still cannot achieve over 21-22volts. I have even tried using hard water from another area and it is still the same. | |
Topic: new to Hidrex PS500 | |
dell Replies: 13 Views: 13645 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Fri May 14, 2010 11:08 pm Subject: new to Hidrex PS500 |
I have tried using the armpit mode but it is still the same. | |
Topic: new to Hidrex PS500 | |
dell Replies: 13 Views: 13645 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Fri May 14, 2010 10:35 am Subject: new to Hidrex PS500 |
Hi Markus I have been trying to use pulsed current lately and i find that I can only get the Hidrex to reach around 21 Volts even though i set it to 60 volts. Up till now I have been using direct curr ... | |
Topic: new to Hidrex PS500 | |
dell Replies: 13 Views: 13645 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Mon May 03, 2010 12:20 am Subject: new to Hidrex PS500 |
Another thing ive noticed is that the instruction manual that comes with the Hidrex says that the max output in Pulsed mode is 35ma at 60V. While on the website it says the max output is 20ma at 60V. ... | |
Topic: Hidrex PS500 | |
dell Replies: 1 Views: 5184 |
Forum: Success board Posted: Sat Apr 10, 2010 4:29 am Subject: Hidrex PS500 |
Just an update on my situation, I seem to have achieved dryness on about 90% of my hands. The only part still sweating is the webbing between my thumb and first finger. I increased the voltage and dur ... | |
Topic: Hidrex PS500 | |
dell Replies: 1 Views: 5184 |
Forum: Success board Posted: Wed Mar 17, 2010 2:41 pm Subject: Hidrex PS500 |
I bought a Hidrex PS 500 and have been using it for about 5 weeks now to treat hyperhidrosis of my hands and feet. I started treating my hands and feet together at 20V using pulsed current (the Hi ... |
|
Topic: Back of the hands | |
dell Replies: 3 Views: 5056 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Tue Mar 16, 2010 12:43 pm Subject: Back of the hands |
Hi Markus, I have been treating my hands daily while wearing cotton gloves, which has reduced the sweating on the back of my hands. However now my palms and fingers are starting to sweat again. I t ... |
|
Topic: Back of the hands | |
dell Replies: 3 Views: 5056 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Wed Mar 10, 2010 2:30 am Subject: Back of the hands |
Hi Markus, What is the best way to treat the backs of the hands as well as the palms? I was thinking of wearing some cotton gloves during treatment (so the whole hand is exposed to the current), do ... |
|
Topic: Output current - Hidrex | |
dell Replies: 5 Views: 6439 |
Forum: General obscurities Posted: Tue Feb 16, 2010 5:03 am Subject: Output current - Hidrex |
OK I think I understand now! I have another question - what is the maximum safe current to treat hands and feet? I read in another post where you have stated - "15 mA for sweaty hands (bec ... |
|
Topic: Output current - Hidrex | |
dell Replies: 5 Views: 6439 |
Forum: General obscurities Posted: Mon Feb 15, 2010 2:56 pm Subject: Output current - Hidrex |
Sorry I am a little confused... So it is the same current output per volt (0.58ma per Volt) regardless of whether im using DC mode or Pulsed mode? Also why does Pulsed mode only go up to a max ... |
|
Topic: Initial treatment for Hidrex PS | |
dell Replies: 3 Views: 4233 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Thu Feb 04, 2010 11:36 pm Subject: Initial treatment for Hidrex PS |
I have read those threads but it is not clear as to how often I should be doing the treatments. The instruction manual says three times a week while your thread seems to say daily. Which one is it ... |
|
Topic: Initial treatment for Hidrex PS | |
dell Replies: 3 Views: 4233 |
Forum: Problems with the treatment - No / only little / partial success board Posted: Thu Feb 04, 2010 1:25 am Subject: Initial treatment for Hidrex PS |
Hi I have just recieved my Hidrex PS and have just read the instruction manual. It says for initial treatment to do three weekly 15 minute treatments. However from reading threads on this forum it see ... | |